TRIALOG COMBOCS
Trialog is working on EV charge since more than 10 years and had several opportunities to develop a strong expertise on EV charge protocols like IEC 61851, DIN 70121, ISO 15118,...
In this context, Trialog has developed ComboCS: a CCS test and validation tool.
SIMULATOR MODE
ComboCS, the CCS simulator is able to simulate either an EV or EVSE (Depends of the ComboCS model) part of a CCS implementation in order to simulate a charging session following IEC 61851-1, DIN 70121 and/or ISO/IEC 15118.
SUPERVISOR MODE
ComboCS is provided with a web interface compatible with Windows, Linux and Mac, accessible over Ethernet or Wifi. It provide access to real-time evolution of the ongoing CCS communication.
TEST CASE MODE
The test case mode of ComboCS triggers CCS communication session for a list of nominal and non-nominal predifined cases :
Conformance tests defined by ISO 15118-4, ISO 15118-5 and DIN 70122 and interoperability tests developped by Trialog.
EXPERT MODE
The expert mode provide means to modify at anytime the nominal behavior of the ComboCS before or during the charging loop.
BRIDGE MODE
When ComboCS Bridge mode is enabled, all PLC trafic is redirected to a Wireshark opened on the operator machine, providing access to the raw Ethernet trafic from SLAC to ISO 15118-2 or DIN 70121 for further analysis.
SNIFFER OPTION
This option allow your ComboCS to act as a passive sniffer and then sniff PLC trafic without interfering in any way with the CCS communication.
PSD MEASUREMENT OPTION
This option allow your ComboCS to calibrate the PLC power emission of your EV/EVSE part in order to be compliant with ISO 15118-3.
POWER TRANSFER OPTION
This option allow the ComboCS to perform simulation and test means of DIN 70121 and ISO 15118 protocols with real power transfer.
The different datasheets
Comparison table of ComboCS and ComboCS4M
ComboCS | ComboCS4M | |
---|---|---|
Simulator Mode | ✅ | ✅ |
Supervisor Mode | ✅ | ✅ |
Test case mode | ✅ | |
Expert mode | ✅ | |
HTTP Control API | ✅ | ✅ |
OCPP 1.6J & 2.0.1 (EVSE only) | Optional | Optional |
ISO 15118-20 V2G | Optional | Optional |
Passive Sniffer | Standalone option | Standalone option |